SVES 59d3c289767a2d0b30e5c34d False 75 28
OK
background image not found
Found results for
'sized enclosure'
EAPL TIMER A SEIRES INR   0 INR  0
-NaN%

EAPL TIMER A SEIRES

Product Features: Din sized enclosure for Track (Din rail) / Screw mounting. Front terminal protective cover for safety. LED indication for timing in progress. A1DA :External (zero volt / potential free) command contact for timing initiation. Dimensions: Over-all: 22.5 X 75 X 102mm (W X H X D). Applications: AMF panels, Automation panels, HT / LT panels, MCC panels, C & R panels, RTCC panels, Transformer panels and many more Model Function Source Voltage Time Range Output Regular A1D1 On-Delay 240V AC 0.3 Secs to 30 Mins. 2 c/o Relay A1D1-X On-Delay X-Version* 0.3 Secs to 30 Mins. 2 c/o Relay A1D1-X (60M) On-Delay X-Version* 0.6 Secs to 60 Mins. 2 c/o Relay A1DE-X Interval X-Version* 0.3 Secs to 30 Mins. 2 c/o Relay A1DCS-X Equal Off/On Cyclic X-Version* 0.6 Secs to 60 Mins. 2 c/o Relay A1DN-X Auxiliary Relay X-Version* 20 mSecs 2 c/o Relay A1D1 On-Delay 8V to 30V DC 0.3 Secs to 30 Mins 2 c/o Relay A1D1(WB) On-Delay (Wide Band) 266V to 456V AC 3 Secs to 30 Secs 1 c/o Relay A1DA Signal Off-Delay 110V AC / 240V AC 0.3 Secs to 30 Mins 1 c/o Relay A1DS Star-Delta 110V AC / 240V AC / 415V AC 0.6secs to 60secs, #TD 40ms / 100ms 1 c/o (C-NO) Star, 1 c/o (C-NO) Delta A1DH-1 Power Off-Delay 240V AC** 18 Secs to 180 Secs 2 c/o Relay Optional A1D-E Interval 8-30V DC 0.3secs to 30mins 2 c/o Relay A1DN-X(80mS) Auxilliary Relay X-Version * 80msecs 1 c/o Relay A1DA Signal Off-Delay 24V DC 0.3secs to 30mins 2 c/o Relay A1DS Star-Delta 240V AC , 60Hz / 24V DC 0.6secs to 60secs, #TD 40ms/100ms 1 c/o (C-NO) Star, 1 c/o (C-NO) Delta A1DH-1 Power Off-Delay 24V DC **/ 240V AC** 0.6secs to 6secs 2 c/o Relay

INR 0 INR 0

Availability:False

Pay mode:COD only

view details
EAPL PRESET COUNTERS INR   0 INR  0
-NaN%

EAPL PRESET COUNTERS

Product Features: Din sized enclosure for panel mounting. Wide Voltage range Front / Rear reset facility provided. Hold / Restart options (selectable) during power failure. Input signal from proximity switch ( NPN / PNP type) or Potential free (zero volt) signal from limit switch, relay o/p etc Over-voltage protection CT-5: Digital, single window 5 digit 7 segment red LED display with up counting for process value. Preset Counts can be programmed with the help of thumbwheel switch H3CT-5U : Digital, single window 5 digit 7 segment red LED display with up counting for both process value and set value Input sensitivity – programmable (1-100Hz) Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: CT-5 – 72 x 72 x 128mm, H3CT-5U – 48 x 48 x 115mm (W x H x D) Applications: Paper board counting, bag counting, bottle counting, relay change over counting, breaker panels, stroke counting in granite cutting m/c and many more Ordering Information: Model Function Source Voltage Range Output Data Sheet Regular CT-5 Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay Click Here H3CT-5U Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL FAULT ANUNCIATORS INR   0 INR  0
-NaN%

EAPL FAULT ANUNCIATORS

Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL DIGITAL TIMER H/C/E SERIES INR   0 INR  0
-NaN%

EAPL DIGITAL TIMER H/C/E SERIES

Product Features: Din Sized enclosuer for panel mounting. Digital dual display for set value and process value. FUNCTION (programmable): ON DELAY / INTERVAL /CYCLIC ADJUSTABLE. TYPE OF START SIGNAL (programable) : NO START / PULSE / CONTINUOUS. One of the relay c/o can be configured as INSTANT or DELAYED. Program lock is provided for function, relay configuration, type of start signal and range selected. RESET cum START facility can be achieved either through front buttons Or Rear terminals HOLD/RESTART facility during power failure conditions. Internal Resettable fuse for protection of device against voltage fluctuations(N.A. for H3PT-MU). Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal Dimensions: Over-all: H3PT-MU – 48 x 48 x 115mm, C3PT-MU, CD6 - 72 x 72 x 128mm, E3PT-MU – 96 x 96 x 117mm (W x H X D) Cut-out: H3PT-MU – 46 x 46 mm, C3PT-MU, CD6 - 69 x 69mm, E3PT-MU – 92 x 92mm (W x H) Applications: Injection moulding machine panels, Granite processing machines, Packaging / Printing machines, Hot stamping machines etc Ordering Information: Model Function Source Voltage Time Selection Output Data Sheet Regular E3PT-MU Multifunction Up-counting 85V AC to 270V AC / DC 0.1secs to 99hrs 59mins 1c/o Instant, 2 c/o Delayed or 3 c/o Delayed Click Here H3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed C3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Optional H3PT-MU Multifunction 12V DC /24V DC 0.1secs to 99 hrs 59mins 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Contact Us CD6 ON-Delay with Instant contact 85V AC to 270V AC / DC 1 sec to 999mins 1c/o Instant, 1 c/o Delayed

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL DIGITAL LCD TACHOMETER INR   0 INR  0
-NaN%

EAPL DIGITAL LCD TACHOMETER

Product Features: Micro-controller based design with world class Indian software. Non-contact sensing through reflected light beam on reflective sticker. LCD display Input sensing indication through LED. Memory facility to retain measured value. Portable, lightweight, strong and elegant ABS enclosure. Accuracy: 1RPM up to 5,000 RPM and 0.05% of the reading above 5,000 RPM. Resolution: 0.1RPM up to 5,999 RPM and 1RPM at and above 6,000RPM. Calibration certificate provided along with tachometer - traceable to national and international standards. Dimensions: Over-all: 72 X 170 X 38mm (W X H X D). Applications: Motors, Pumps, Generators, Engines and many more Ordering Information: Model Function Source Voltage Range Data Sheet DT 2001 B Digital Hand Held Non Contact Tachometer 6V DC (4x1.5V, 'AA' size Batteries) 1 to 99,999 RPM (with one reflecting mark) Click Here

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL TIMER A1D1-X INR   0 INR  0
-NaN%

EAPL TIMER A1D1-X

Product Features: Din sized enclosure for Track (Din rail) / Screw mounting. Front terminal protective cover for safety. LED indication for timing in progress. A1DA :External (zero volt / potential free) command contact for timing initiation. Dimensions: Over-all: 22.5 X 75 X 102mm (W X H X D). Applications: AMF panels, Automation panels, HT / LT panels, MCC panels, C & R panels, RTCC panels, Transformer panels and many more Model Function Source Voltage Time Range Output CSA Approved CE Approved Data Sheet Regular A1D1 On-Delay 240V AC 0.3 Secs to 30 Mins. 2 c/o Relay √ √ Click Here A1D1-X On-Delay X-Version* 0.3 Secs to 30 Mins. 2 c/o Relay √ √ A1D1-X (60M) On-Delay X-Version* 0.6 Secs to 60 Mins. 2 c/o Relay √ √ A1DE-X Interval X-Version* 0.3 Secs to 30 Mins. 2 c/o Relay √ √ A1DCS-X Equal Off/On Cyclic X-Version* 0.6 Secs to 60 Mins. 2 c/o Relay √ - A1DN-X Auxiliary Relay X-Version* 20 mSecs 2 c/o Relay √ √ A1D1 On-Delay 8V to 30V DC 0.3 Secs to 30 Mins 2 c/o Relay - Click Here A1D1(WB) On-Delay (Wide Band) 266V to 456V AC 3 Secs to 30 Secs 1 c/o Relay - - A1DA Signal Off-Delay 110V AC / 240V AC 0.3 Secs to 30 Mins 1 c/o Relay - - A1DS Star-Delta 110V AC / 240V AC / 415V AC 0.6secs to 60secs, #TD 40ms / 100ms 1 c/o (C-NO) Star, 1 c/o (C-NO) Delta - - A1DH-1 Power Off-Delay 240V AC** 18 Secs to 180 Secs 2 c/o Relay - - Optional A1D-E Interval 8-30V DC 0.3secs to 30mins 2 c/o Relay - - Contact Us A1DN-X(80mS) Auxilliary Relay X-Version * 80msecs 1 c/o Relay - - A1DA Signal Off-Delay 24V DC 0.3secs to 30mins 2 c/o Relay - - A1DS Star-Delta 240V AC , 60Hz / 24V DC 0.6secs to 60secs, #TD 40ms/100ms 1 c/o (C-NO) Star, 1 c/o (C-NO) Delta - - A1DH-1 Power Off-Delay 24V DC **/ 240V AC** 0.6secs to 6secs 2 c/o Relay - - *X-Version: 24V AC to 240V AC, 24V DC to 220VDC, **Minimum 2secs of aux, supply required for each cycle, else timer may malfunction #TD- Transfer Delay time to change from star to delta

INR 0 INR 0

Availability:False

Pay mode:COD only

view details
EAPL TIMER- B1DCA-T INR   1350 INR  1350
-0%

EAPL TIMER- B1DCA-T

Product Features: Din sized enclosure for Track (Din rail) / Screw mounting. B1DCA-T : HOLD / RESTART facility during power fail conditions. B1DCA-T : Auto / Manual switch for mode of operation B1DCA-T : Program - enable / disable facility for tamper proof operation. B1DCA-X, B1DCA-T : Independently selectable ON & OFF time. SPP-T :Trips under phase missing, phase reversal or phase unbalance In manual mode, terminals provided to connect to switch so as to manually switch ON and switch OFF load Dimensions: Over-all: 45 X 75 X 116mm (W X H X D).

INR 1350 INR 1350

Availability:True

Pay mode:COD only

view details
1
false