SVES 59d3c289767a2d0b30e5c34d False 75 28
OK
background image not found
Found results for
'single window'
EAPL PRESET COUNTERS INR   0 INR  0
-NaN%

EAPL PRESET COUNTERS

Product Features: Din sized enclosure for panel mounting. Wide Voltage range Front / Rear reset facility provided. Hold / Restart options (selectable) during power failure. Input signal from proximity switch ( NPN / PNP type) or Potential free (zero volt) signal from limit switch, relay o/p etc Over-voltage protection CT-5: Digital, single window 5 digit 7 segment red LED display with up counting for process value. Preset Counts can be programmed with the help of thumbwheel switch H3CT-5U : Digital, single window 5 digit 7 segment red LED display with up counting for both process value and set value Input sensitivity – programmable (1-100Hz) Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: CT-5 – 72 x 72 x 128mm, H3CT-5U – 48 x 48 x 115mm (W x H x D) Applications: Paper board counting, bag counting, bottle counting, relay change over counting, breaker panels, stroke counting in granite cutting m/c and many more Ordering Information: Model Function Source Voltage Range Output Data Sheet Regular CT-5 Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay Click Here H3CT-5U Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL FAULT ANUNCIATORS INR   0 INR  0
-NaN%

EAPL FAULT ANUNCIATORS

Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL DIGITAL TEMPERATURE CONTROLLER INR   0 INR  0
-NaN%

EAPL DIGITAL TEMPERATURE CONTROLLER

Product Features: Universal Input (J,K,PT-100) Selectable. Wide Voltage Range. ON / OFF or Self-Tuned Function Selectable. Single / double set point. Over Voltage Protection Compensation offset feature available in TX7-Ua User Friendly Programming through increment / decrement button (TX7-ua) Indication for sensor, funtion and relay status. Program enable / disable for sensor, function, hystersis, compensation features in TX7-Ua. Dimension 72x72x128.5 Dimensions: Overall: H3-TX Models -48 x 48 x 115mm, TX7 Models- 72 X 72 X 128mm; EX9 Models- 96 x 96 x 117mm (W x H X D) Cut-out: H3-TX Models – 46 x 46mm, TX7 Models - 69 x 69mm , EX9 Models – 92 x 92mm (W x H) Ordering Information: Model Function Source Voltage Sensor Range Output Data Sheet Regular 85-270V AC / DC H3TX-2H-U 2 set point temp.controller (Heater Type) J K PT-100 (ON-OFF) 0°C - 600°C 0°C - 1200°C 0°C - 300°C 2 relay 1 c/o, 5A Click Here TX7-2H-U EX9-2H-U H3TX-2A-U 2 set point temp.controller (Alarm Type) TX7-2A-U EX9-2A-U *Function applicable only for H3TX-Ua, TX7-Ua, EX9-Ua, H3TX-2U, TX7-2U, EX9-2U and H3TX-Ub ** Offset applicable only for H3TX-Ua, TX7-Ua, EX9-Ua, H3TX-Ub

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
1
false