SVES 59d3c289767a2d0b30e5c34d False 75 28
OK
background image not found
Found results for
'light switch'
Low Pressure Differential Pressure switch INR   0 INR  0
-NaN%

Low Pressure Differential Pressure switch

We Deals in Low Pressure Differential Pressure switch Range 200-1000 Pascal, 50-500 Pascal, 500-2500 Pascal

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL SMPS INR   0 INR  0
-NaN%

EAPL SMPS

Product Features: Compact, light weight and SMPS design Versatile and easy snap-on mounting on Din-rail Very low ripple and noise Regulated and adjusted output Protection against over voltage, short circuit and over load. Dimensions: Overall: MS-01 - 45 x 75 x 116mm, MS-02 – 110 x 86 x 71mm , MS-03 - 155 x 88 x 79mm, MS-04 - 172x150x78mm MS-05 – 22.5 x 75 x 97mm (W x H x D) Applications: PLC, DC Panels, DC Solenoids, DC Relay boards, Battery Charging Panels, etc. Ordering Information: Model Function Source Voltage Output Data Sheet Voltage Ampere Watt Regular MS-01 Switch Mode Power Supply 192V-264V AC 24V DC 1A 24W Click Here 12V DC 1A 12W MS-02 Switch Mode Power Supply 170V-300V AC 24V DC 0.63A 15W Click Here 24V DC 1.04A 25W 24V DC 1.46A 35W 24V DC 2.1A 50W 12V DC 1.25A 15W 12V DC 2.08A 25W 12V DC 2.9A 35W 12V DC 4.2A 50W 5V DC 6A 30W MS-03 Switch Mode Power Supply 170 – 300V AC 24V DC 5A 120W Click Here MS-05 Switch Mode Power Supply 170 – 300V AC 5V DC 1A 5W Click Here Optional MS-04 Switch Mode Power Supply 190V-270V AC 24V DC 10A 240W Contact Us Electronic Timers A-Series B-Series Digital Timers H-Series S-Series Programmable Fault Annunciator

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL SOLAR CHARGE CONTROLLER INR   0 INR  0
-NaN%

EAPL SOLAR CHARGE CONTROLLER

Product Features: Maximum Power Point Tracking technology increases the efficiency of PV system. Advanced Interleaved buck topology Full electronic protection (Reverse Polarity, Over-Voltage and Over-Current). Multi-stage Battery charging:- Boost/ Absorption/ Trickle Modes. For Lumina-02 :MPPT protects battery from being discharged below lower cut-off voltage.Automatic Dusk to Dawn Load ON feature.Efficient in charging Lead Acid Batteries. Dimensions: Dimension:149 x 86 x 77mm(WxHxD) Applications: Solar street light, Roof top solar solutions, Solar Home systems Ordering Information: Model Function Battery Voltage DataSheet Lumina-01 MPPT Solar Charge Controller 12V Click Here Lumina-03 Lumina-02 24V

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL PHOTOCELL CONTROLLER INR   0 INR  0
-NaN%

EAPL PHOTOCELL CONTROLLER

Product Features: This is a light switch working on direct or reflective transmission principle. It consists of high intensity emitter source and high sensitive receiver The signal received from the receiver will operate a relay with ON delay or OFF delay depending on mode selected. The time range can be 0.3 sec / 30 sec. Dimensions: EALS-4505 Dimension:45 x 75 x 116mm(WxHxD) EALSR-01:19.2 x 35.5 x 127.5mm (W x H x D) EALSE-01:19.2 x 35.5 x 127.5mm (W x H x D) Applications: Hopper Feed Control,Stop Motion Device, Light Barriers, Level Control, Intrusion Alarm.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL PRESET COUNTERS INR   0 INR  0
-NaN%

EAPL PRESET COUNTERS

Product Features: Din sized enclosure for panel mounting. Wide Voltage range Front / Rear reset facility provided. Hold / Restart options (selectable) during power failure. Input signal from proximity switch ( NPN / PNP type) or Potential free (zero volt) signal from limit switch, relay o/p etc Over-voltage protection CT-5: Digital, single window 5 digit 7 segment red LED display with up counting for process value. Preset Counts can be programmed with the help of thumbwheel switch H3CT-5U : Digital, single window 5 digit 7 segment red LED display with up counting for both process value and set value Input sensitivity – programmable (1-100Hz) Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: CT-5 – 72 x 72 x 128mm, H3CT-5U – 48 x 48 x 115mm (W x H x D) Applications: Paper board counting, bag counting, bottle counting, relay change over counting, breaker panels, stroke counting in granite cutting m/c and many more Ordering Information: Model Function Source Voltage Range Output Data Sheet Regular CT-5 Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay Click Here H3CT-5U Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL DIGITAL TIME SWITCH INR   0 INR  0
-NaN%

EAPL DIGITAL TIME SWITCH

Product Features: Switches On and Off 4 times in a day with respect to real time. LED indication for relay status, LCD display for real time clock. User friendly programming with manual over ride facility. Clock hour and Clock minute buttons can be enabled by shorting terminals to program RTC. For TS-203, TS-203B : Use (1.5Vx2)AA size Batteries Dimensions: TS-203 :Over-all:72 x 72 x 84mm (W x H x D) TS-203B : Over-all:110 x 86 x 68mm (L x W x D) Applications: Street lightings,advertising sign boards etc Ordering Information: Model Function Source Voltage Output Data Sheet TS-203 Digital Daily 4 program time switch 240V AC 1 C/O Relay,16A Click Here TS-203B Digital Daily 4 program time switch 240V AC 1 C/O Relay,16A

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL FAULT ANUNCIATORS INR   0 INR  0
-NaN%

EAPL FAULT ANUNCIATORS

Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL DIGITAL TIMER H/C/E SERIES INR   0 INR  0
-NaN%

EAPL DIGITAL TIMER H/C/E SERIES

Product Features: Din Sized enclosuer for panel mounting. Digital dual display for set value and process value. FUNCTION (programmable): ON DELAY / INTERVAL /CYCLIC ADJUSTABLE. TYPE OF START SIGNAL (programable) : NO START / PULSE / CONTINUOUS. One of the relay c/o can be configured as INSTANT or DELAYED. Program lock is provided for function, relay configuration, type of start signal and range selected. RESET cum START facility can be achieved either through front buttons Or Rear terminals HOLD/RESTART facility during power failure conditions. Internal Resettable fuse for protection of device against voltage fluctuations(N.A. for H3PT-MU). Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal Dimensions: Over-all: H3PT-MU – 48 x 48 x 115mm, C3PT-MU, CD6 - 72 x 72 x 128mm, E3PT-MU – 96 x 96 x 117mm (W x H X D) Cut-out: H3PT-MU – 46 x 46 mm, C3PT-MU, CD6 - 69 x 69mm, E3PT-MU – 92 x 92mm (W x H) Applications: Injection moulding machine panels, Granite processing machines, Packaging / Printing machines, Hot stamping machines etc Ordering Information: Model Function Source Voltage Time Selection Output Data Sheet Regular E3PT-MU Multifunction Up-counting 85V AC to 270V AC / DC 0.1secs to 99hrs 59mins 1c/o Instant, 2 c/o Delayed or 3 c/o Delayed Click Here H3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed C3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Optional H3PT-MU Multifunction 12V DC /24V DC 0.1secs to 99 hrs 59mins 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Contact Us CD6 ON-Delay with Instant contact 85V AC to 270V AC / DC 1 sec to 999mins 1c/o Instant, 1 c/o Delayed

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
1
false