SVES 59d3c289767a2d0b30e5c34d False 75 28
OK
background image not found
Found results for
'distribution'
EAPL MULTIFUNCTION METER INR   0 INR  0
-NaN%

EAPL MULTIFUNCTION METER

Product Features: Microcontroller based multifunction AC Energy Meter. Accuracy Class1.0 / (Class 0.5 calibration on Request). CT /PT (Pri/Sec) Programmable. Digital Measurement. IEC 62052-11 IEC 62053-21 IEC 62053-22 IEC 62053-23. RS 485 Serial Port with Modbus RTU Output. Flush / Panel Mounting . 96 x 96 mm DIN Mounting. Auto Scroll / Hold Facility. Internal Resettable fuse for protection of device against voltage fluctuations. Protection from dust and water as per IP-51. Dimensions: Overall: 96 * 96 * 117mm (W x H x D) Cut-out: 92 * 92mm (W x H) Applications: Sub metering panels, Distribution Panels, HT/ LT panels, DG panels etc. Ordering Information: Model Function Source Voltage Data Sheet Regular EMS-01 Multi Function Meter 85 V to 270 V AC / DC Click Here EMS-03 KWH Meter Click Here EMS-09 Basic / Energy Meter EMS-17 Dual Source Energy Meter Click Here Optional EMS-01 Multi Function Meter 24V DC contact-us EMS-03A KWh meter 85V-270V AC/DC

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL FAULT ANUNCIATORS INR   0 INR  0
-NaN%

EAPL FAULT ANUNCIATORS

Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL DC MULTI FUNCTION METER INR   0 INR  0
-NaN%

EAPL DC MULTI FUNCTION METER

Product Features: Micro Controller based 3 Channel DC Energy Meter. Displays DC parameters V, I, KW, KWh ,MWh& Load on hours of all three channels. Displays one set old Energy readings and Communication status. Display Hold / Scroll Facility available. Programmable Shunt ratios. Alphanumeric display for Parameter & values RS-485 serial port with Modbus RTU output. Wide Input Voltage and Current Range. Protection from dust and water as per IP-51. Dimensions: Overall:96 x 96 x 117mm (W x H x D) , Cutout: 92 x 92mm(W x H) Applications: DC rectifier systems, Battery panels, DC distribution solar panels,DC loads,DC motors etc Ordering Information: Model Function Source Voltage Input Voltage Parameter Data Sheet Regular SNM-01 DC Energy meter 110-240V AC/DC +/-10% 80V DC to 220V DC Page 1 (load1) V, A, KW, KWh,MWh,LH Click Here Page 2 (load 2) V, A, KW, KWh,MWh,LH Page 3 (load 3) V, A, KW, KWh,MWh,LH Page 4 (Old) KWh,MWh,LH (load 1, Load 2, load 3) Page 5 (Communication ) Communication status, Dev Id SNM-02 24-48V DC +/-10% 21V DC to 50V DC Page 1 (load1) V, A, KW, KWh,MWh,LH Page 2 (load 2) V, A, KW, KWh,MWh,LH Page 3 (load 3) V, A, KW, KWh,MWh,LH Page 4 (Old) KWh,MWh,LH (load 1, Load 2, load 3) Page 5 (Communication ) Communication status, Dev Id SNM-03 110 to 240V AC/DC+/-10% 5V to 1000V Voltage,Current,Wattage,Energy,Energy,Load Hours,Old Energy,Old Energy,Old Load Hours,DEVICE-ID & Comm. Status V, A, KW, KWh,MWh,LH,Old KWh,Old MWh,Old LH,Communication Status

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
1
false