SVES 59d3c289767a2d0b30e5c34d False 75 28
OK
background image not found
Found results for
'connect'
EAPL FAULT ANUNCIATORS INR   0 INR  0
-NaN%

EAPL FAULT ANUNCIATORS

Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL ENERGY MANAGEMENT SYSTEM INR   0 INR  0
-NaN%

EAPL ENERGY MANAGEMENT SYSTEM

Product Features: EMS-18: VAF Meter with True RMS Sensing, High brightness red LED display On site programmable CT(pri &sec) ratio Protection from dust and water as per IP-51 for front facia Measurement of basic parameters Program enable /disable facility available EMS-11: Measurement of current parameters (L-N) *CT primary and secondary programmable. EMS-12: Measurement of voltage parameters *PT primary and secondary programmable. EMS-13: Measurement of frequency parameter. EMS-14: Measurement of Power Factor parameter. EMS-02: Measurement of basic parameters.(Current (L-N), Voltage (L-N),(L-L), frequency (average) and Power factor (Total) * CT ratio programmable, RS485 Mod-bus RTU protocol available, Sensing : True RMS . Program can be locked by removing short link connected across specified terminals Hold/Scroll Facility available . Dimensions: For EMS-11,EMS-12,EMS-13,EMS-14 Overall: 96 x 96 x 97.5mm (W x H x D) * Cutout : 92 x 92mm (W x H) For EMS-02,EMS-18 Overall: 96 x 96 x 117 mm (W x H x D) * Cutout : 92 x 92mm (W x H) Applications: Sub metering, machines, Panels, power analysis systems etc. Ordering Information: Model Function Source Voltage Parameter Datasheet Regular EMS-11 Ammeter 240V AC -15% to +10% A(R, Y, B) Click Here EMS-12 Voltmeter V (R, Y, B), V(RY, YB, BR) EMS-13 Frequency Meter Hz. (Avg) EMS-14 Power Factor Meter 85V-270V AC/DC PF(R,Y,B), TPF EMS-18 VAF Meter V(R, Y, B), V(RY, YB, BR), A(R,Y, B), Hz Click Here EMS-02 VAF / PF Meter V(R, Y, B), V(RY, YB, BR), A(R,Y, B), Hz, PF(T)

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL TIMER- B1DCA-T INR   1350 INR  1350
-0%

EAPL TIMER- B1DCA-T

Product Features: Din sized enclosure for Track (Din rail) / Screw mounting. B1DCA-T : HOLD / RESTART facility during power fail conditions. B1DCA-T : Auto / Manual switch for mode of operation B1DCA-T : Program - enable / disable facility for tamper proof operation. B1DCA-X, B1DCA-T : Independently selectable ON & OFF time. SPP-T :Trips under phase missing, phase reversal or phase unbalance In manual mode, terminals provided to connect to switch so as to manually switch ON and switch OFF load Dimensions: Over-all: 45 X 75 X 116mm (W X H X D).

INR 1350 INR 1350

Availability:True

Pay mode:COD only

view details
1
false